EasyManua.ls Logo

Graco 190ES 232900 - On;Off Switch Replacement (240 Vac)

Graco 190ES 232900
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17309063
On/Off Switch Replacement
240 Vac (232906)
Removal
1.
Relieve pressure; page 6.
2. Fig. 8. Remove pressure control cover (39).
3. Disconnect four wires (A) at ON/OFF switch (23).
4. Remove toggle boot (25) and locking ring (24).
Remove ON/OFF switch (23).
Installation
1. Install new ON/OFF switch (23). Install locking ring
(24) and toggle boot (25).
2. Connect four wires (A) to ON/OFF switch.
3. Install pressure control cover (39).
ti0055b
Fig. 8
39
A
23
36
52
E
D
25
24
C
35
37
18
L1L2
TP1 TP2
Pressure
Transducer
ON/OFF
Switch
Power
Plug
Potentiometer
from Motor
Filter Board
Red (+)
Wiring Diagram
Heat from inductor coil of filter board
may destroy wire insulation that
comes in contact with it. Exposed
wires could cause shorts and com-
ponent damage. Bundle and tie all
loose wires so none lay in contact
with inductor coil of filter board.
Caution
Yellow
Brown
TI0058
Capacitor
Blue
Black (–)
Brown
Blue
Green/Yellow
22
Black/White (–)
Red/White (+)

Related product manuals