Instructions--Parts List
308118P
EN
SEVERE -DUTY, UHMWPE/PTFE PACKED
Stainless Steel Pumps
55 gallon (200 liter) drum size, with bung adapter.
For transfer and supply of solventborne and waterborne finishing materials.
For profession al use only.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
See page 2 for table of contents.
Model 224348, Series C
10:1 Ratio Presidentr Pump
Model 256713, Series A
10:1 Ratio Presidentr Pump (1.5 in. F emale Inlet)
1800 psi (12.4 MPa, 124 bar) Maximum Fluid Working Pressure
180 psi (1.25 MPa, 12.5 bar) Maximum Air Inlet Pressure
Model 224350, Series C
5:1 Ratio Mon arkr Pump
Model 256714, Series A
5:1 Ratio Mon arkr Pump (1.5 in. F emale Inlet)
900 psi (6.3 MPa, 63 bar) Maximum Fluid Working Pressure
180 psi (1.25 MPa, 12.5 bar) Maximum Air Inlet Pressure
0200A
MODEL 224348 SHOWN
2575
II 1/2 G T2
ITS03ATEX11228
2575
II 1/2 G T2
ITS03ATEX11228

Questions and Answers

  • J
    Johnathan SantosAug 9, 2025
    How to fix low output on the up stroke of a Graco Water Pump?
    • S
      smilesAug 9, 2025
      If the Graco Water Pump operates, but the output is low on the up stroke, the fluid piston valve or packings may be held open or worn. Clear or service them.
  • T
    Tonya BaileyAug 15, 2025
    Why does my Graco Water Pump fail to operate?
    • S
      Sarah WiseAug 15, 2025
      If the Graco Water Pump fails to operate, several factors could be at play. It might be due to a restricted line or inadequate air supply, in which case you should clear any obstructions and increase the air supply. Alternatively, there might be insufficient air pressure, or the air valves are closed or clogged. Make sure to open and clean them. Another reason might be exhausted fluid supply. Refill it and purge all air from the pump and fluid lines.
  • I
    iburgessAug 21, 2025
    What to do if my Graco Water Pump output is low on both strokes?
    • D
      Danny BlackAug 21, 2025
      If your Graco Water Pump operates but the output is low on both strokes, consider these potential causes: a restricted line or inadequate air supply (clear any obstructions and increase air supply); insufficient air pressure or closed/clogged air valves (open and clean the valves); exhausted fluid supply (refill and purge air from the pump and fluid lines); or a clogged fluid line or valves (clear the clogs). Also, check if the packing nut is too tight (loosen it) or too loose, or the throat packings are worn (tighten the packing nut or replace the throat packings).
  • S
    sara42Aug 27, 2025
    Why is my Graco Water Pump operation erratic or accelerated?
    • D
      Dwayne JohnsonAug 27, 2025
      If the Graco Water Pump operates erratically or accelerates unexpectedly, first check if the fluid supply is exhausted. If so, refill it and purge all air from the pump and fluid lines. Also, a held open or worn intake valve, a held open or worn fluid piston valve or packings might be the reason. Clear or service them.
  • G
    George GarciaSep 2, 2025
    What causes low output on the down stroke of my Graco Water Pump?
    • B
      Brianna Nguyen DDSSep 2, 2025
      If your Graco Water Pump operates, but the output is low on the down stroke, the intake valve may be held open or worn. Clear or service it.

Summary

Symbols

Warning Symbol

Alerts to serious injury or death if instructions are not followed.

Installation

Grounding

Details the procedure for grounding the pump and system components.

Operation

Pressure Relief Procedure

Details steps to safely relieve system pressure before servicing or operation.

Starting and Adjusting the Pump

Guides on priming, starting, and adjusting the pump for operation.

Troubleshooting

Service

Technical Data (10:1 President)

Technical Data (5:1 Monark)

Graco 224350 Specifications

General IconGeneral
Model224350
CategoryWater Pump
BrandGraco
Power SourceCompressed Air
TypeAir-powered diaphragm pump
Maximum Pressure100 PSI
Fluid Inlet Size1 in
Fluid Outlet Size1 in
Inlet/Outlet Size1 inch NPT
Air Inlet Size1/4 inch
Materials of ConstructionPolypropylene, Santoprene