Questions and Answers

  • C
    christopherriveraAug 11, 2025
    How to fix a Graco 312585G Pressure Washer when the pump fails to operate?
    • J
      Jose BarnesAug 11, 2025
      If the pump fails to operate, several issues could be the cause. First, there might be a restricted line or inadequate air supply, or closed or clogged valves. Clear any obstructions and increase the air supply, ensuring all valves are open. Second, the fluid hose or gun/valve could be obstructed, or the fluid hose ID might be too small. Open and clear any blockages and use a hose with a larger ID. Another potential cause is fluid dried on the displacement rod. Clean the rod and always stop the pump at the bottom of the stroke, keeping the wet-cup 1/3 filled with compatible solvent. Lastly, dirty, worn, or damaged motor parts can cause the pump to fail. Clean or repair these parts.
  • B
    Breanna FoxAug 17, 2025
    Why is the output low on both strokes of my Graco 312585G Pressure Washer pump?
    • K
      kenneth35Aug 18, 2025
      If your pump operates but the output is low on both strokes, consider these possibilities: There may be a restricted line or inadequate air supply, or closed or clogged valves; clear any obstructions and increase the air supply, and check that all valves are open. The fluid hose or gun/valve could be obstructed, or the fluid hose ID might be too small; open and clear any blockages, and use a hose with a larger ID. Ensure the bleeder valve is closed. Finally, worn packings in the displacement pump can cause low output; replace the packings.
  • C
    Courtney RiosAug 25, 2025
    What to do if my Graco Pressure Washer pump speed is erratic or accelerated?
    • J
      Jocelyn AlvarezAug 25, 2025
      If you notice erratic or accelerated pump speed, there are a few potential causes. First, check if the fluid supply is exhausted; if so, refill and prime the pump. Another cause could be a held open or worn piston valve or packings; clear the valve and replace the packings. Finally, a held open or worn intake valve could be the issue; clear the valve and service it.
  • F
    floydalexAug 29, 2025
    What causes low output on the upstroke of my Graco 312585G Pressure Washer pump?
    • M
      Matthew ZamoraAug 30, 2025
      If the pump operates, but the output is low on the upstroke, the issue might be a held open or worn piston valve or packings. To resolve this, clear the valve and replace the packings.
  • S
    Sarah MillerSep 4, 2025
    What to do if the Graco 312585G Pressure Washer pump operates, but output is low on the down-stroke?
    • J
      Joshua Mueller DDSSep 4, 2025
      If the pump operates, but the output is low on the down-stroke, the problem may be a held open or worn intake valve. Clear the valve and service it.