EasyManua.ls Logo

Graco 395 - Spin Test; Armature, Brushes, and Motor Wiring Open Circuit Test; Armature Short Circuit Test; Motor Brush Replacement

Graco 395
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 309674
Spin Test
Setup
Electric Shock Hazard; page 4.
To check armature, motor winding and brush electrical
continuity:
1.
Relieve pressure; page 4.
2. Remove drive housing; page 19.
3. Fig. 3. Remove pressure control cover (50). Dis-
connect connector (F).
4. Fig. 4. Remove motor shroud (23) and inspection
covers (A).
Armature Short Circuit Test
Quickly turn motor fan by hand. If no electrical shorts,
motor coasts two or three revolutions before complete
stop. If motor does not spin freely, armature is
shorted. Replace motor; page 20.
Armature, Brushes, and Motor Wiring Open
Circuit Test (Continuity)
1. Connect red and black motor leads with test lead.
Turn motor fan by hand at about two revolutions
per second.
2. If uneven or no resistance, check for: broken brush
springs, brush leads, motor leads; loose brush
terminal screws, motor lead terminals; worn
brushes. Repair as needed; page 10.
3. If still uneven or no resistance, replace motor;
page 20.
Fig. 3
F
50
ti2572a
Motor Brush Replacement
395/495 Motor Brush Removal
Replace brushes worn to less than 1/2 in. Brushes
wear differently on each side of motor, check both
sides. Brush Repair Kit 287016 is available. Spring
clip, 112766, may be purchased separately.
1. Read General Repair Information; page 4.
2.
Relieve pressure; page 4.
3. Fig. 4. Remove motor shroud (23) and two inspec-
tion covers (A).
(Continued on page 11)
A
23
Fig. 4
ti2571a

Related product manuals