EasyManua.ls Logo

Graco EcoQuip EQ200T - Troubleshooting

Graco EcoQuip EQ200T
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Troubleshooting Troubleshooting
Troubleshooting
Problem Problem
Problem
Cause Cause
Cause
Solution Solution
Solution
Theairsupplyisinadequate.Makesuretheairinletpressuregaugereads
100-125psi(6.8–8.6bar,0.68–0.86MPa).If
thegaugedoesnotread100–125psi,check
theaircompressorforpropersetup.
TheEmergencyStopis
engaged.
DisengagetheEmergencyStop.
Inadequatewatersupplytothe
pump.
Makesurethewatertankisfullandtheinlet
ballvalveisopen.
Thepotpressureregulatorisset
toolow.
Increasethesettingonpotpressureregulator.
Thepop-upcannotsealproperly.
Cleanallabrasivefromthepop-upandgasket.
Makesurethepop-upspringisliftingandthe
pop-upis󰘰rmlyagainsttheseal.Ifcleaning
doesnotsolveissue,replacepop-upgasket.
TheAuto-Ventvalvewillnot
seal.
SeeCleaningtheAuto-VentValve,page30.
Thepotpressurereliefvalveis
dischargingwater.
Decreasethepotpressureto145psi(10.3
bar,1.03MPa)orless.Ifthevalveweepsor
relievesat145psi,replacevalve.
Thepotorpumpisleaking
pressure.
Makesuretheabrasiveballvalveandthe
dumpvalveareclosed.Ifpotpressure
gaugestillcreepsdownward.See
CheckingforLeaks,page25.
Thepotwillnotproperly
pressurize.
Thepotpressureregulatoris
malfunctioning.
Replacethepotpressureregulatorassembly.
Theairsupplyisinadequate.Makesuretheairinletpressuregaugereads
100-125psi(6.8–8.6bar,0.68–0.86MPa).If
thegaugedoesnotread100–125psi,check
theaircompressorforpropersetup.
Theblastairregulatoris
malfunctioning.
Replacetheblastairregulator.
Theblastpressurewill
notreachthedesiredset
point.
Themainairregulatoris
malfunctioning.
SeeRepairingtheMainAirRegulator,page
27.
22
334666C

Related product manuals