Startup
334558D 21
11. Inspect for leaks. If leaks occur, turn
sprayer OFF immediately. Perform
Pressure Relief Procedure, page 13.
Tighten leaky fittings. Repeat Startup
procedure steps 2-8. If no leaks, con-
tinue to trigger gun until system is thor-
oughly flushed.
12. Place siphon tube in paint pail.
13. Trigger gun again into flushing fluid pail
until paint appears.
Switch Tip
™
and Guard
Assembly
1. Perform Pressure Relief Procedure,
page 13.
2. Engage gun trigger lock. Insert Switch
Tip. Insert seat and OneSeal™.
3. Insert Switch Tip and face forward.
4. Screw assembly onto gun. Tighten.
High-pressure spray is able to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.