Cleanup
26 3A6400A
8. Turn prime valve forward to SPRAY position.
Trigger gun into flushing pail to purge fluid from
hose.
9. Raise siphon tube above flushing fluid and run
sprayer for 15 to 30 seconds to drain fluid. Turn
pump switch and engine OFF
10. Turn prime valve down DRAIN position.
11. Remove filters from gun and sprayer, if installed.
Clean and inspect. Install filters.
12. If flushing with water, flush again with mineral
spirits, or Pump Armor, to leave a protective coating
to prevent freezing or corrosion.
13. Wipe sprayer, hose and gun with a rag soaked in
water or mineral spirits.
ti2776a