308441 13
Troubleshooting
PROBLEM CAUSE SOLUTION
Fluid in exhaust air. Diaphragm ruptured. Replace. See pages 1719.
Loose diaphragm shaft bolt (107). Tighten or replace. See pages
1719.
Damaged o-ring (108). Replace. See pages 1719.
Pump exhausts excessive air at
stall.
Worn air valve block (7), o-ring (6),
plate (8), pilot block (18), u-cups
(10), or pilot pin o-rings (17).
Repair or replace. See pages
1415.
Worn shaft seals (402). Replace. See pages 1719.
Pump leaks air externally. Air valve cover (2) or air valve cover
screws (3) are loose.
Tighten screws. See page 15.
Air valve gasket (4) or air cover
gasket (22) is damaged.
Inspect; replace. See pages 1415,
2021.
Air cover screws (25) are loose. Tighten screws. See pages 2021.
Pump leaks fluid externally from ball
check valves.
Loose manifolds (102, 103), dam-
aged seal between manifold and
seat (201), damaged o-rings (202).
Tighten manifold bolts (106) or re-
place seats (201) or o-rings (202).
See page 16.