Startup
3A4980B 13
4. Install cover and ring onto cup. Tighten
ring securely.
5. Connect FlexLiner System to gun.
6. Connect air hose to inlet fitting of gun.
7. Verify trigger slide is in SPRAY position
(A).
8. With HVLP sprayer powered ON, point
gun into a waste area. Evacuate air from
FlexLiner System by holding gun
vertically and pull trigger open until a
continuous spray pattern is observed.
NOTE: Tilt gun back and forth to help in
evacuation of air.
9. You are now ready to spray. Reference
How to Spray, page 16.
ti30709a