EasyManua.ls Logo

Graco LineLazer v 3900 - Layout Mode and Pump Operation Issues

Graco LineLazer v 3900
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
3A3388A Operation 53
LAYOUT MODE
No dots or poor dots in
Layout and Marking
Mode.
Too small of Dot setting. Increase Dot size, page 39.
Gun is not activated. Press the 1 or 2 button on control to activate a
gun.
Cable is not adjusted properly. Adjust Cable to properly actuate gun trigger,
page 20.
Tip clog. Clear tip or Replace tip.
Battery voltage is too low. Charge battery or replace battery.
Pump is not on, or pressure is not set. Turn on pump and increase pressure to a mini-
mum of 200 psi.
Problem Cause Solution

Table of Contents