DataTrak Operation
22 3A7004B
Replace DataTrak Battery or Fuse
Replace Battery
1. Unscrew cable from the back of the reed switch
assembly. See F
IG. 6.
2. Remove the cable from the two cable clips.
3. Remove DataTrak module from bracket. See F
IG. 7.
Take module and attached cable to a non-hazard-
ous location.
4. Remove two screws on back of module to access
battery.
5. Disconnect the used battery and replace with an
approved battery. See Table 2.
To reduce the risk of fire and explosion, the battery
and fuse must be replaced in a non-hazardous loca-
tion.
Use only an approved replacement battery, shown
in T
ABLE 2, and an approved fuse, shown in TABLE 3.
Use of an unapproved battery or fuse will void
Graco’s warranty and Intertek and Ex approvals.
F
IG. 6. Disconnect DataTrak
F
IG. 7. Remove DataTrak
ti11992a
Cable
Reed
Switch
Assembly
ti11884a
Table 2. Approved Batteries
Energizer® brand alkaline # 522
Varta® brand alkaline # 4922
Ultralife® brand lithium # U9VL
Duracell® brand alkaline # MN1604

Related product manuals