EasyManuals Logo

Graco Merkur User Manual

Graco Merkur
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
Models
6 3A7004B
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks.
When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this
manual where applicable.
WARNING
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or solvent
flowing through the equipment can cause static sparking. To help prevent fire, explosion, and electric
shock:
Electrostatic equipment must be used only by trained, qualified personnel who understand the
requirements of this manual.
Ground all equipment, personnel, object being sprayed, and conductive objects in or close to spray
area. Resistance must not exceed 1 megohm. See Grounding instructions.
Only use grounded Graco conductive air supply hoses.
Do not use pail liners unless they are conductive and grounded.
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until
you identify and correct the problem.
Check gun resistance, hose resistance, and electrical grounding daily.
Use and clean equipment only in well ventilated area.
Interlock the gun air and fluid supply to prevent operation unless ventilation air flow is above the
minimum required value.
Use only Group IIA or Group D materials.
Never spray of flush solvent at high pressure.
To clean the exterior of the equipment, cleaning solvents must have a flash point at least
15°C or 59° F above ambient temperature. Non-ignitable fluids are preferred.
Always turn the electrostatics off when flushing, cleaning or servicing equipment.
Eliminate all ignition sources such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static sparking).
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
Keep work area free of debris, including solvent, rags and gasoline.
Keep the spray area clean at all times. Use non-sparking tools to clean residue from the booth and
hangers.
Keep a working fire extinguisher in the work area.
PRESSURIZED EQUIPMENT HAZARD
Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause
serious injury.
Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning,
checking, or servicing equipment.
Tighten all fluid connections before operating the equipment.
Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Merkur and is the answer not in the manual?

Graco Merkur Specifications

General IconGeneral
Fluid DeliveryUp to 4.0 gpm (15.1 lpm)
Air Inlet Size1/4 in npsm
Fluid Inlet Size1/2 in npsm
Fluid Outlet Size1/4 in npsm
Maximum Air Input Pressure100 psi (0.7 mpa)
Maximum Fluid Pressureup to 3300 psi (22.7 mpa)
Pump TypeAir-Operated Piston Pump
Flow Rateup to 4.0 gpm (15.1 lpm)
PowerAir operated
Inlet/Outlet SizeFluid Inlet: 1/2 in npsm, Fluid Outlet: 1/4 in npsm

Related product manuals