Component Identification
312796S 7
Grounding
See FIG. 2. Verify that the ground screw (GS) is attached
and tightened securely to the air motor. Connect the
other end of the ground wire (U) to a true earth ground.
Accessories
Bleed-type master air valve
Required in your system to relieve air trapped
between it and the air motor when the valve is
closed.
Be sure the valve is easily accessible from the pump
and located downstream from the air regulator.
Air regulator
Adjusts air pressure to the motor and fluid outlet pres-
sure of pump. Locate it close to the pump. Install a
gauge to read air pressure.
Air filter
Removes harmful dirt and moisture from compressed
air supply.
FIG. 2: Ground wire
GS U
ti12914a
Trapped air can cause the pump to cycle unexpectedly,
which could result in serious injury from splashing or
moving parts.