Operation
18 334659G
3. Hold gun perpendicular, 10-12 in. (25-30
cm) from surface. Spray back and forth;
overlap by 50%.
4. Trigger gun after moving. Release
trigger before stopping. For additional
spraying information, see separate gun
manual.
Clear Tip Clog
1. Release trigger. Engage trigger lock.
Rotate Spray Tip. Disengage trigger
lock. Trigger gun at waste area to clear
clog.
2. Engage trigger lock. Return Spray Tip to
original position. Disengage trigger lock
and continue spraying.