Loading...
RunScreens
Standby Standby
Standby
Mode Mode
Mode
Operation Operation
Operation
InStandbyMode,theatomizingairandthe󰘱uid
pressurepilotregulatorsaresettozero(0).The
󰘱owmeterremainsoperational,andthesystem
willshow󰘱uid󰘱owandaccumulated󰘱uidvolume.
Residualpressuremaybeinthesystemdepending
onthenatureoftheairand󰘱uidregulators,material
properties,andothervariances.
Whenthesystemis󰘰rstpoweredup,thetypeof
󰘱uidinthesystemisunknown.Thisisindicatedwith
checkerboardpatternonthegun.Aftera󰘱uidFill
process,thegunisshownasblacktoindicatethatit
isloadedwithsprayablematerial.Aftera󰘱uidFlush
process,thegunisshownaswhitetoindicatethat
itisloadedwithsolvent.
Table Table
Table
2 2
2
Standby Standby
Standby
Mode Mode
Mode
Run Run
Run
Screens Screens
Screens
Description Description
Description
Examples Examples
Examples
Standbyafter
power-upwithan
unknown󰘱uid
Standbywith
paintloaded
Standbywith
solventloaded
ThefollowingiconsareavailableontheRunScreen
inStandbyMode:
Key Key
Key
Enterthescreen.
Atomizingairregulator
Flowratetarget(ClosedLoopFlow
ControlMode)
%pilotairpressuretargetto󰘱uid
regulator
Pressuretarget(ClosedLoopPressure
Mode)
Current(mA)setpointtopilotaircontrol
Current󰘱uidpressure
StandbyModeUnknown󰘱uidinsystem
StandbyModeSystem󰘰lledwith
sprayablematerial
StandbyModeSystem󰘰lledwith
solvent
MovebetweenRunScreens.