EasyManua.ls Logo

Graco ProControl 1KE Plus - Run Registers

Graco ProControl 1KE Plus
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AppendixA-ModbusVariableMap
Run Run
Run
Registers Registers
Registers
Allregistersare32-bit.
Address Address
Address
Description Description
Description
Permissions Permissions
Permissions
Units Units
Units
Low Low
Low
High High
High
Notes Notes
Notes
402000Date,YearRead/WriteYY199Limitedto2099
402002Date,MonthRead/WriteMM112
402004Date,DayRead/WriteDD131
402006Time,HourRead/WriteHH023
402008Time,MinuteRead/WriteMM059
402010
Time,Second
Read/Write
SS
059
402012AlarmsNeeding
Acknowledgment
Read/Write
Bit󰘰eld
032-bit
SeeAlarmBit󰘰eld
Table,page83
402014
CurrentGrandTotal
Read
cc
032-bit
402016
CurrentBatchTotal
Read/Write
cc
0999999Write0toreset
402018
CurrentMaintenanceTotal
Read/Write
cc
09999999Write0toreset
402020
CurrentFlowRate
Readcc/min065535
402022
CurrentPressure
Readbar032-bit
Scaledas1bar=
65536
402024Unused
402026
CalibrationMode
Read/WriteBit01
0=Off
1=On
402028
Calibration,Measured
Volume
Read/Write
cc
032-bit
402030
Calibration,Actual
DispensedVolume
Read/Write
cc
032-bit
402032DispenseModeRead/Write
Selection
03
0=Standby
1=Flush
2=Fill
3=Dispense
402034
GunTriggerOnTime
Read
ms
032-bit
402036
CurrentJobSprayTotal
Read
cc
024-bit
402038
CurrentJobFlushTotal
Read
cc
024-bit
402040
CurrentJobNumber
Read/WriteValue032-bitAutomatically
increments
402042JobAttributeRead/WriteValue032-bit
Useforidenti󰘰cation
oftheuser,station,
part,etc.
402044
JobGunTriggerTime
Read
ms
032-bit
402046Unused
402048Unused
823A6948A

Table of Contents