Warnings
WARNING
ELECTRIC ELECTRIC
ELECTRIC
SHOCK SHOCK
SHOCK
HAZARD HAZARD
HAZARD
Thisequipmentmustbegrounded.Impropergrounding,setup,orusageofthesystemcan
causeelectricshock.
Turnoffanddisconnectpoweratmainswitchbeforedisconnectinganycablesandbefore
servicingorinstallingequipment.
Connectonlytogroundedpowersource.
Allelectricalwiringmustbedonebyaquali󰘰edelectricianandcomplywithalllocalcodes
andregulations.
Donotexposetorain.Storeindoors.
INTRINSIC INTRINSIC
INTRINSIC
SAFETY SAFETY
SAFETY
Intrinsicallysafeequipmentthatisinstalledimproperlyorconnectedtonon-intrinsicallysafe
equipmentwillcreateahazardousconditionandcancause󰘰re,explosion,orelectricshock.
Followlocalregulationsandthefollowingsafetyrequirements.
InstallationshouldbeinaccordancewithANSI/ISARP12.06.01“InstallationofIntrinsically
SafeSystemsforHazardous(Classi󰘰ed)Locations”andtheNationalElectricalCode®
(ANSI/NFPA70).
InstallationinCanadashouldbeinaccordancewiththeCanadianElectricalCode,CSA
C22.1,Part1,AppendixF.
ForATEX,installperEN60079–14andapplicablelocalandnationalcodes.
Equipmentthatcomesincontactwithintrinsicallysafeterminalsmustmeettheentity
parameterrequirementsspeci󰘰edinControlDrawing16M169.SeeAppendixAinManual
332013.Thisincludessafetybarriers,DCvoltagemeters,ohmmeters,cables,and
connections.Removetheunitfromthehazardousareawhenservicing.
Ifaprinter,computer,orotherelectricalcomponentisconnected,itmustbeusedin
conjunctionwithasafetybarrier.
Withoutthesafetybarrier,theequipmentisnolongerintrinsicallysafeandmustnotbe
operatedinhazardouslocations,asde󰘰nedinarticle500oftheNationalElectricalCode
(USA)oryourlocalelectricalcode.
Donotinstallequipmentapprovedonlyfornon-hazardouslocationinahazardousarea.See
theIDlabelfortheintrinsicsafetyratingforyourmodel.
Donotuseintrinsicallysafeequipmentwithapowersupplythathasnobarrier.Intrinsic
safetymaybecompromised.
Groundthepowersupply.Avoltagelimitingsafetybarriermustbeproperlygroundedtobe
effective.Forpropergrounding,usea12gaugeminimumgroundwire.Thebarrier’sground
mustbewithin1ohmoftrueearthground.
Donotremoveanycoveruntilpowerhasbeenremoved.
Donotsubstitutesystemcomponentsasthismayimpairintrinsicsafety.
332013E5

Other manuals for Graco ProControl 1KE Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco ProControl 1KE Plus and is the answer not in the manual?

Graco ProControl 1KE Plus Specifications

General IconGeneral
BrandGraco
ModelProControl 1KE Plus
CategoryControl Unit
LanguageEnglish

Related product manuals