AppendixA-ModbusVariableMap
Address Address
Address
Description Description
Description
Permissions Permissions
Permissions
Units Units
Units
Low Low
Low
High High
High
Notes Notes
Notes
403036PercentageDrive
MinimumSetpoint
Read/WritePercent099.0
Scaledas1%=65536
Activewhen403094=0
403038
System,FlowRate
Maximum
Read/Write
cc
0999000
UsedforF3alarm
403040
System,FlowRate
Minimum
Read/Write
cc
0999000
UsedforF2alarm
403042
System,Meter
K-Factor
Read/Writecc/pulse0x028F0x3E7FFFF1cc=65536
403044
System,Pressure
TransducerType
Read/WriteValue030=NotInstalled
1=16H282100psi
2=16P289500psi
3=15M6697500psi
403046
System,Pressure
TransducerOffset
Read/WritemV
403048
System,Pressure
TransducerScale
Read/WritemV/bar
403050
System,Job
VolumeUnits
Read/WriteValue020=cc
1=l
2=gal
403052
System,Pressure
Maximum
Read/Writebar00x44E584
Scaledas1bar=65536
UsedforP3alarm
403054
System,Pressure
Minimum
Read/Writebar00x44E584
Scaledas1bar=65536
UsedforP2alarm
403056Display,Pressure
AlarmEnable
Read/Writebar01
0=Off
1=On
UsedforP3andP2alarms
403058
Softwareversion
identi󰘰er
Read/WriteValue032-bit
403060PasswordRead/WriteValue09999
403062Flowalarmrange
aspercentageof
setpoint
Read/WriteBit01
403064Flowalarmrange
percentageof
setpoint
Read/WriteValue099
403066Pressurealarm
rangeas
percentageof
setpoint
Read/WriteBit01
403068Pressurealarm
rangepercentage
ofsetpoint
Read/WriteValue099
403070UnusedRead/Write
403072Loggedjob
maximumtarget
Read/Write
cc
0999999
403074Loggedjob
minimumtarget
Read/Write
cc
0999999
403076Loggedjobtarget
alarmenable
Read/WriteBit01
403078Display,Pressure
AlarmAutoClear
Read/WriteBit01
0=Off
1=On
UsedforP3andP2
deviations
3A6948A85