3A5411J
EN
Instructions
Pulse
®
TLM (Tank
Level Monitor)
Measures the distance between the device and the surface of the fluid beneath it to
determine the volume of fluid within a tank. Use with a Pulse operating system only.
Intended fluids: oil, waste oil, automatic transmission fluid (ATF), anti-freeze, windshield
washer solution, and waste water.
Not approved for use in European explosive atmosphere locations. For professional use
only.
Part No.: 25M449
Contains Model XBee S2C Radio, IC: 1846A-XBS2C.
The TLM contains FCC ID MCQ-XBS2C. This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including interference that may cause
undesired operation.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
NOTICE
•
Do not over tighten TLM into tank
bung! Over tightening can cause perma-
nent damage and result in inaccurate
readings.
• Do not use thread sealant or adhesive!
Many of these products are chemically
incompatible with the ABS plastic. PTFE
tape is acceptable.