Troubleshooting
Error Location Type Description
Cause Solution
L1AX ADM
Low Chemical Level
A
Low material level.
Refill material and update
drum lev el on ADM
Maintenance screen.
Alarm can be disa bled on
the System Setup s creen.
L1BX ADM
Low Chemical Level
B
Low material level.
Refill material and update
drum lev el on ADM
Maintenance screen.
Alarm can be disa bled on
the System Setup s creen.
MMUX
USB
Maintenance Due -
USB
USB logs have
reached a level
where data loss
will occur if logs are
not downloaded.
InsertaUSBdriveintothe
ADM and download all logs.
Pressure
differenc e betwe en
AandBmaterial
is greater than the
defined value.
Ensure material ow is
equally restricted on both
material lines.
Pressure
imbalance is
defined too low.
Ensure that the pressure
imbalance va lue, on the
System Setup screen, is at
an acceptable maximum
pressure to prevent
unnecessary alarms and
abort di s pen se s.
Out of material.
Fill tanks with material
Fluid leaking from
heater in let rupture
disk.
Check if heater
and PRESSURE
RELIEF/SPRAY valve are
plugged. Clear. Replace
rupture disk. Do not replace
withapipeplug.
P0AX
MCM
Pressure Imbalance
AHigh
Feed system
defective.
Checkfeedpumpand
hoses for blo ck age. Ch eck
that feed pumps have
correct air pressure.
333024F 19