Troubleshooting
System
Before performi ng any troublesh ooti ng proc edu res:
1. Relieve Pressure. See Pressure Relief Procedure, page 43.
2. Turn main power switch OFF.
3. Allow equipment to cool.
Problem Cause Solution
No power.
Turn main power switch ON.
Failed 24 V power supply. Replace power supply.
Reactor ADM does not turn on.
Failed surge protector. Replace surge protector.
Loose connections.
Check MCM
connection 13.
Tripped circuit breaker (CB02). Reset breaker, see Repair Circuit
Breaker Module, page 55.Check
240VAC at output of breaker.
Electric motor does not operate.
Shorte
d windings. Replace motor, see
Repair Electric Motor, page 54.
Electric motor runs erratically. Failed motor bearing. Replace motor, see
Repair Electric Motor, page 54.
333024F 35