Troubleshooting
Error Location Type Description
Cause Solution
Incorrect software
version.
Inse rt a system token into
the ADM module and cycle
the power. Wait until the
upload is complete before
removing the token.
WBC0 MCM Software Version
Error
MCM does not
have line voltage.
If V1CM also exists, see
troubleshooting for V1CM.
The software version
cannot be read if the MCM
does not have line voltage.
WMI0
TCM
TCM Fan Error Fan inside TCM
is not operating
properly.
Check for debris in the TCM
fan and clear with forced air
if necessary.
WSUX USB Configuration Error
USB
Avalid
configuration file
can't be found for
the USB.
Inset a system token into
the ADM and cycle power.
Wait until t he lights on the
USB port stop ashing
before removing token.
WXUD ADM
USB Dow nload Error
Log download
failed.
Backup and reformat the
USB drive. Retry download.
WXUU ADM
USB Upload Error Custom language
lefailedtoupload.
Perform normal USB
download and use the new
disptext.txtletouploadthe
custom language.
34 333024F