Technical Specications
Technical Specifications
Reactor 2 Hydraulic Proportioning System
U.S.
Metric
Maximum Fluid Working Pressure for B a re Proportioners
Models H-30, H-40,
and H-50
2000 psi 13.8 MPa, 138 bar
Models H-XP2 and H-XP3 3500 psi 24.1 MPa, 241 bar
Minimum Fluid Working Pressure for Bare Proportioners
H-30 700psi 4.8MPa,48bar
H-40, H-50 600 ps i 4.1 MPa, 41 bar
H-XP2 1200 psi 8.2 MPa, 82 bar
H-XP3 850 ps i 5.8 MPa, 58 bar
Fluid: Oil Pres
sure Ratio
Model H-40 1.91 : 1
Models H-30 and H-50 1.64 : 1
Models H-XP2
and H-XP3
2.79 : 1
Fluid Inlets
Component A (ISO) 3/4 npt(f), 300 psi maximum 3/4 npt(f), 2.07 MPa, 20.7
bar maximum
Component B (RES) 3/4 npt(f), 300 psi maximum 3/4 npt(f), 2.07 MPa, 20.7
bar maximum
Fluid Outlets
Componen
tA(ISO)
#8 1/2 in.
JIC, with #5 5/16 in. JIC adapter
Component B (RES) #10 5/8 in. JIC, with #6 3/8 in. JIC adapter
Fluid Circulation Ports
1/4 npsm(m)
250 psi 1.75 MPa, 17.5 bar
Maximum Fluid Temperature
190° F 88° C
Maximum Output (10 weight oil at ambient temperature)
Model H-30
28 lb/min (60 Hz) 13 kg/min (60 Hz)
Model H-XP2
1.5 gpm (60 Hz) 5.7 liter/min (60 Hz)
Model H-50
52 lb/min (60 Hz) 24 kg/min (60 Hz)
Mo
del H-40
45 lb/min (60 Hz) 20 kg/min (60 Hz)
Model H-XP3
2.
8 gpm (60 Hz)
10
.6 liter/min (60 Hz)
Output Per Cycle (A and B)
Model H-40 0.063 gal. 0.24 liter
Models H-30 and H-50 0.074 gal. 0.28 liter
Models H-XP2 and H-XP3 0.042 gal. 0.16 liter