Repair
309574L 43
Heated Hose
Check Hose Connectors
2. Relieve pressure, page 9.
3. Disconnect hose electrical connector (D) at Reac-
tor, F
IG. 16.
4. Using an ohmmeter, check between the two termi-
nals of hose connector (D). There should be conti-
nuity.
5. If hose fails test, retest at each length of hose,
including whip hose, until failure is isolated.
Check FTS Cables
2. Relieve pressure, page 9.
3. Disconnect FTS cable (F) at Reactor, F
IG. 16.
4. Test with ohmmeter between pins of cable connec-
tor.
5. If cable fails test, retest at FTS, page 44.
Refer to the heated hose manual 309572 for hose
replacement parts.
1. Turn main power OFF . Disconnect power
supply.
Whip hose must be connected.
1. Turn main power OFF . Disconnect power
supply.
Pins Result
1 to 2 approximately 35 ohms per 50 ft (15.2 m) of
hose, plus approximately 10 ohms for FTS
1 to 3 infinity ()
FIG. 16. Heated Hose
When inserting contact into connector (D) ensure
that notch of contact snaps over edge of spring
clip as shown in the cutaway drawing. See F
IG.
17.
F
IG. 17 Connector
TI2726a
F
D
Inserting Contact
Contact
Spring Clip
D
TI8367
Contact fully inserted and correctly
snapped onto spring clip.
Spring Clip
Contact
D
TI8368A

Other manuals for Graco REACTOR E-30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco REACTOR E-30 and is the answer not in the manual?

Graco REACTOR E-30 Specifications

General IconGeneral
Maximum Fluid Temperature190°F (88°C)
Max Fluid Pressure3000 psi
Heater Wattage6000 W
Power Requirements3-phase, 230V
TypeElectric
Heater Voltage230V
Fluid Outlet Size3/8 in
Voltage230V
Spray Tip Size0.015 - 0.035 in

Related product manuals