312067H 3
Models
E-20 SERIES
E-30 SERIES
E-XP1 SERIES
E-XP2 SERIES
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix
chamber sizes may be less.
Total system watts, based on maximum hose length for each unit:
E-20 and E-XP1 series, 210 ft (64 m) maximum heated hose length, including whip hose.
E-30 and E-XP2 series, 310 ft (94.5 m) maximum heated hose length, including whip hose.
Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum
flow.
Part, Series
Full Load Peak
Amps*
Nominal Voltage
Range (phase)
System
Watts†
Primary
Heater
Watts
Max Flow
Rate
lb/min
(kg/min)
Approximate
Output per Cycle
(A+B)
gal. (liter)
Maximum Fluid
Working Pressure
psi (MPa, bar)
259025, G 48 200-240 V (1) 10,200 6,000 20 (9) 0.0104 (0.0395) 2000 (14, 140)
259030, G 24 350-415 V (3) 10,200 6,000 20 (9) 0.0104 (0.0395) 2000 (14, 140)
259034, G 32 200-240 V (3) 10,200 6,000 20 (9) 0.0104 (0.0395) 2000 (14, 140)
Part, Series
Full Load Peak
Amps*
Nominal Voltage
Range (phase)
System
Watts†
Primary
Heater
Watts
Max Flow
Rate
lb/min
(kg/min)
Approximate
Output per Cycle
(A+B)
gal. (liter)
Maximum Fluid
Working Pressure
psi (MPa, bar)
259026, F 78 200-240 V (1) 17,900 10,200 30 (13.5) 0.0272 (0.1034) 2000 (14, 140)
259031, F 34 350-415 V (3) 17,900 10,200 30 (13.5) 0.0272 (0.1034) 2000 (14, 140)
259035, F 50 200-240 V (3) 17,900 10,200 30 (13.5) 0.0272 (0.1034) 2000 (14, 140)
259057, F 100 200-240 V (1) 23,000 15,300 30 (13.5) 0.0272 (0.1034) 2000 (14, 140)
259058, F 62 200-240 V (3) 23,000 15,300 30 (13.5) 0.0272 (0.1034) 2000 (14, 140)
259059, F 35 350-415 V (3) 23,000 15,300 30 (13.5) 0.0272 (0.1034) 2000 (14, 140)
Part, Series
Full Load Peak
Amps*
Nominal Voltage
Range (phase)
System
Watts†
Primary
Heater
Watts
Max Flow
Rate
gpm (lpm)
Approximate
Output per Cycle
(A+B)
gal. (liter)
Maximum Fluid
Working Pressure
psi (MPa, bar)
259024, G 69 200-240 V (1) 15,800 10,200 1.0 (3.8) 0.0104 (0.0395) 2500 (17.2, 172)
259029, G 24 350-415 V (3) 15,800 10,200 1.0 (3.8) 0.0104 (0.0395) 2500 (17.2, 172)
259033, G 43 200-240 V (3) 15,800 10,200 1.0 (3.8) 0.0104 (0.0395) 2500 (17.2, 172)
Part, Series
Full Load Peak
Amps*
Nominal Voltage
Range (phase)
System
Watts†
Primary
Heater
Watts
Max Flow
Rate
gpm (lpm)
Approximate
Output per Cycle
(A+B)
gal. (liter)
Maximum Fluid
Working Pressure
psi (MPa, bar)
259028, F 100 200-240 V (1) 23,000 15,300 2.0 (7.6) 0.0203 (0.0771) 3500 (24.1, 241)
259032, F 35 350-415 V (3) 23,000 15,300 2.0 (7.6) 0.0203 (0.0771) 3500 (24.1, 241)
259036, F 62 200-240 V (3) 23,000 15,300 2.0 (7.6) 0.0203 (0.0771) 3500 (24.1, 241)

Other manuals for Graco REACTOR E-30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco REACTOR E-30 and is the answer not in the manual?

Graco REACTOR E-30 Specifications

General IconGeneral
Maximum Fluid Temperature190°F (88°C)
Max Fluid Pressure3000 psi
Heater Wattage6000 W
Power Requirements3-phase, 230V
TypeElectric
Heater Voltage230V
Fluid Outlet Size3/8 in
Voltage230V
Spray Tip Size0.015 - 0.035 in