RotoFlex™ HD Pump
14 310645F
Hose Break-In Procedure
1 Make sure fluid flow
regulator (K) is turned all
the way down.
2 Pour approxi-
mately 1 gallon
hot
water in
sprayer hopper
to lubricate the
pump.
3 Turn power switch (A) on.
4 Hold in prime switch (P).
5 Turn fluid flow regulator
(K) up to full pressure.
6 Run sprayer dry for 1 to 1-1/2 minutes.