2150 Specifications
24 3A5999E
2150 Performance Chart
FLUID FLOW -- gpm (lpm)
(Pump tested in
water with inlet
submerged)
AIR PRESSURE
D 120 psi air (8.4 bar, 0.84 MPa)
C 100 psi air (7 bar, 0.7 MPa)
B 70 psi air (4.8 bar, 0.48 MPa)
A 40 psi air (2.8 bar, 0.28 MPa)
FLUID OUTLET PRESSURE psi (bar, MPa)
AIR CONSUMPTION scfm (m
3
/min)
A
B
C
D
0
0
20
(1.4, 0.14)
40
(2.8, 0.28)
60
(4.1, 0.41)
80
(5.5, 0.55)
100
(6.9, 0.69)
120
(8.3, 0.83)
140
(9.7, 0.97)
20
(76)
40
(151)
60
(227)
80
(303)
100
(379)
120
(454)
140
(530)
160
(606)
180
(681)
200
(757)
0
0
20
(76)
40
(151)
60
(227)
80
(303)
100
(379)
120
(454)
140
(530)
160
(606)
180
(681)
200
(757)
50
(1.34)
100
(2.68)
150
(4.02)
200
(5.36)
250
(6.70)
A
B
C
D
FLUID FLOW -- gpm (lpm)
To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow (gpm/lpm) and
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
fluid outlet pressure curve.
3. Follow left to scale to read fluid outlet pressure.
To find Pump Air Pressure
(scfm or m
3
/min) at a specific fluid flow (gpm/lpm) and
operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected air
consumption curve.
3. Follow left to scale to read fluid outlet pressure.