Technical Data
Technical Data
Maximum Fluid
Working Pressure
650 psi (4.5 MPa, 44.8 bar)
Maximum Air Inlet Pressure
100 psi (0.7 M
Pa, 6.9 bar)
Maximum Recommended Pump Speed 60 cycles/min, 4 gpm (15 liters/min) delivery
Air Consumption
See Performance Chart
Pump Cycle
s per Gallon (3.8 Liters)
13.3
Ratio 6:1
Maximum Fluid Temperature
250°F (12
1°C)
Maximum Ambient Temperature (Air
Motor)
120°F (49°C)
Air Inle
t
1/2 npt (f)
Air Exhaust
3/4 npt
(m)
Fluid Inlet Type
2.3 in (5.8 cm) Priming Piston with ange for 6 in. (15.2 cm) Clamp
Fluid Outlet 1-1/2 in. (3.8 cm) Tri-clam
Weight
35 lb
(16 kg)
Wetted Parts
316 Stainless Steel, Buna-N, Polychloroprene, Nitrile, Nylon,
UHMWPE. Certain models have PTFE packings.
Sound data
So
und power*
78.5 dBA
Sound pressure**
71.6 dBA
* Sound power at 70 psi (0.48 MPa, 4.8 bar), 20 cpm. Sound power measured per ISO-9614-2.
** Sound pressure was tested 3.28 feet (1 m) from equipment.