Troubleshooting
312359R 69
Optional User-Settable Spray Limits
*P2AX
P2BX
Pressure exceeded
advisory limits.
Spray Pressure exceeded high or
low advisory limits for more
than 15 seconds.
Same as P5A or P5B above.
*QPDX Pot life timer expired.
Mixed fluid will cure in
hoses, mixer, and gun.
Spray Have not sprayed enough
volume to keep fresh mixed
fluid in the integration hose,
mixer, whip hose, and spray
gun.
Spray fluid, or flush. Resets when
you leave spray mode. Follow
Spray, page 41, or Flush, page
44.
*T2DA
T2DB
Temperature exceeded
advisory limits.
Spray Fluid temperature exceeded
high or low limits for more than
four minutes.
Same as T5A or T5B above.
*T5DA
T5DB
Temperature exceeded
alarm limits.
Spray Fluid temperature exceeded
high or low alarm limits for
more than four minutes.
If fluid temperature is too low,
return to circulation mode to
increase fluid temperature. Adjust
heater set point if needed. Follow
Heat Fluid, page 40.
If fluid temperature is too high,
lower heater set point, and return
circulation mode to cool. Follow
Heat Fluid, page 40.
Adjust temperature target setpoint.
Follow Heat Fluid, page 40.
Alarm
Code
Alarm Problem When Active Cause Solution