Operation, Repair, and Parts
XP
and XP-h
Proportioners
Mechanically linked fixed ratio plural-component system used for proportioning, mixing, and
spraying two component coatings. For professional use only.
Not approved for use in explosive atmospheres or hazardous locations except where indicated in
the Models section.
See Models section (starting on page 10) for model
numbers, descriptions, and agency approval
designations.
Important Safety Instructions
Read all warnings and instructions in this
manual and in related manuals before using
this equipment. Save these instructions.
WLE
3A0420ZAF
EN

Table of Contents

Other manuals for Graco XP70

Questions and Answers

  • L
    Lindsay WeaverSep 23, 2025
    What causes relief valve leaks back to supply, opens too soon, or will not close in Graco Airbrushes?
    • D
      Daniel TaylorSep 23, 2025
      If the relief valve in your Graco Airbrushes leaks back to the supply, opens too soon, or will not close, it is likely that the relief valve is dirty or damaged. Replace the over pressure relief valve.
  • M
    Michael BrownAug 23, 2025
    What to do if relief valve leaks on Graco Paint Sprayer?
    • V
      Vanessa SotoAug 23, 2025
      If the relief valve on your Graco Paint Sprayer leaks back to the supply, opens too soon, or won't close, it indicates that the relief valve is either dirty or damaged. Replace the over pressure relief valve.
  • L
    Linda HuynhAug 25, 2025
    Why does my Graco Paint Sprayer run erratically?
    • R
      robin62Aug 26, 2025
      If your Graco Paint Sprayer system speeds up or runs erratically, it could be due to empty fluid containers, so check them often and keep them filled. Another cause might be air in the fluid lines; purge the lines and check the connections. Also, worn or damaged displacement pump parts can cause this issue; in that case, repair the pump.
  • K
    Katherine WareAug 27, 2025
    What to do if resin output pressure drops on both strokes of Graco XP70 Paint Sprayer?
    • E
      Elizabeth ClarkAug 27, 2025
      If your Graco Paint Sprayer pump operates, but the resin output pressure drops on both strokes, it could be due to a hardener output restriction. Clean and unplug the hardener side, and open the manifold restrictor. Alternatively, the fluid supply might be low, so refill or change the container.
  • H
    hrochaAug 27, 2025
    What to do if hardener output pressure drops on both strokes of Graco Paint Sprayer?
    • U
      ujacksonAug 27, 2025
      If your Graco Paint Sprayer pump operates, but the hardener output pressure drops on both strokes, it could be due to a resin output restriction. Clean and unplug the resin side. Alternatively, the fluid supply might be low, so refill or change the container.
  • C
    Clinton WhitakerSep 18, 2025
    What causes fluid leak under packing nut of Graco Airbrushes?
    • A
      Aaron WalkerSep 18, 2025
      A fluid leak under the packing nut of your Graco Airbrushes may be due to the packing cartridge o-ring. Replace the cartridge o-ring.
  • C
    Christina HartSep 15, 2025
    What causes pressure and flow surges on upstroke with Graco Airbrushes?
    • L
      Laura DixonSep 15, 2025
      Pressure and flow surges on the upstroke with Graco Airbrushes can occur if the feed pressure is too high. Every 1 psi of feed pressure adds 2 psi during the upstroke. Reduce the feed pressure to resolve this issue.
  • F
    fosterraymondSep 16, 2025
    What causes fluid leak in packing nut of Graco Airbrushes?
    • J
      Justin BatesSep 16, 2025
      A fluid leak in the packing nut of your Graco Airbrushes is often caused by a loose packing nut or worn throat packings. Try tightening the packing nut and replacing the throat packings.
  • M
    Michael PenaSep 6, 2025
    How to fix fluid leak under packing nut of Graco Paint Sprayer?
    • R
      Ronald AtkinsSep 6, 2025
      If you observe a fluid leak under the packing nut of your Graco Paint Sprayer, it's likely due to the packing cartridge o-ring. You'll need to replace the o-ring.
  • S
    Seth JohnsonSep 3, 2025
    What to do if hardener output pressure drops on downstroke of Graco Paint Sprayer?
    • D
      Denise CurrySep 3, 2025
      If your Graco Paint Sprayer pump operates, but the hardener output pressure drops on the downstroke, it could be due to a dirty, worn, or damaged hardener pump intake valve. In this case, you should clean and repair the pump.

Summary

Warnings

Electrical and Fire Hazards

Covers risks of electric shock, fire, and explosion.

Personal Safety Hazards

Details risks like skin injection, moving parts, and toxic exposure.

Equipment Misuse and PPE

Addresses improper use and necessary personal protective equipment.

Important Isocyanate Information

Isocyanate Conditions and Handling

Discusses conditions affecting isocyanates and safe handling.

XP Models

Volume Mix Ratios and Specifications

Details mix ratios and specifications for XP models.

XP Proportioning Pump Packages

Pump Package Details

Comprehensive table of XP pump packages with mix ratios and specifications.

Component Identification

System Components

Setup

Grounding Procedures

Essential information on grounding for safety and static discharge prevention.

Connecting Power

Detailed instructions for connecting electrical power to the system.

Operation

Pressure Relief Procedure

Critical procedure for safely relieving system pressure before servicing.

Priming the System with Fluids

Steps to prime the system with A and B fluids before operation.

System Priming Steps (XP and XP-h)

Specific priming steps for XP and XP-h systems.

Recirculation and Heating Procedures

Procedures for recirculating material and heating fluid.

Spraying Procedure

Steps for initiating and performing the spraying process.

Flushing Mixed Material

Procedure for flushing mixed material from the system.

Empty and Flush Entire System

Procedure for emptying and flushing the complete system.

Empty System Procedure

Steps to empty the system of material.

Flush System Procedure

Steps to flush the system with solvent.

Park and Shutdown Procedures

Instructions for safely parking and shutting down the system.

System Verification and Mix Tests

Daily tests to verify system operation, mixing, and integration.

Maintenance

Troubleshooting

Startup and Erratic Operation Issues

Troubleshooting common startup and erratic operation problems.

Pump Malfunction Diagnosis

Guide to diagnose pump malfunctions using fluid gauges.

Repair

Parts

Technical Specifications

Graco XP70 Specifications

General IconGeneral
Fluid Output2.0 gpm (7.6 lpm)
Fluid Delivery2.0 gpm (7.6 lpm)
Maximum Fluid Working Pressure7250 psi (500 bar)
Maximum Air Input Pressure100 psi (7 bar)
Fluid Outlet Size3/8 in npsm(m)
Wetted PartsStainless Steel, PTFE, UHMWPE
Maximum Pressure7250 psi (500 bar, 50 MPa)
Hose Length50 ft