EasyManua.ls Logo

Graco Xtreme Mix - User Manual

Graco Xtreme Mix
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001
309623F
Installation
Xtreme Mix
, Xtreme Mix
185,
and ProMix Easy
Data Download Kit
Part No. 246322
For use with Xtreme Mix units located in a non-hazardous location.
Includes data download software CD (15B734) and RS-232 cable (15A926).
Part No. 246397
For use with Xtreme Mix units located in a hazardous location.
Includes data download software CD (15B734) and RS-232 cable with barrier (15B816).
Part No. 248404
For use with ProMix Easy and Xtreme Mix 185 units located in a non-hazardous location.
Includes data download software CD (15E074) and RS-232 cable (15A926).
Part No. 248403
For use with ProMix Easy and Xtreme Mix 185 units located in a hazardous location.
Includes data download software CD (15E074) and RS-232 cable with barrier (15B816).
WARNING
To reduce the risk of fire and explosion, which could cause serious injury and property damage, the PC
must be in a non-hazardous location.
If connecting RS-232 cable to a unit used in a hazardous location, a safety barrier must be installed
between the PC and unit. Use Kit 246397/248403 and see F
IG. 2 for installation requirements.
Except as noted, instructions in this manual apply to both ProMix Easy and Xtreme Mix units,
which are referred to as “the unit”.

Questions and Answers

  • Z
    zsandersAug 6, 2025
    What to do if the Graco Xtreme Mix Industrial Equipment program does not start?
    • M
      Michael FletcherAug 6, 2025
      If the Graco program isn't starting, here are a few things to check: * First, ensure that the power is on. * Make sure cable 118342 and any adapters are fully seated at both the PC and the connected ports. * See if any other programs are using the same PC communication port. Communication conflicts often occur with fax and handheld computer software, so close or deactivate any potentially conflicting software. * You can also try switching to another PC communication port. * If you're using Hyper Terminal, try closing and restarting it. * Press the PC Enter key multiple times to see if the main menu appears. * To isolate the problem, try communicating with a different PC, RS-232 cable, or ProMix Easy, XtremeMix or XtremeMix 185 system, if available.

Graco Xtreme Mix Specifications

General IconGeneral
BrandGraco
ModelXtreme Mix
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals