Prime
Prime
1. Follow Press
ure Relief Procedure, page 14.
2. Lock gun tri
gger. Remove tip and tip guard from
gun.
3. Place sucti
on tube in the material that will be
sprayed.
Note
Do not stretch hose tight let it hang to
assist uid ow into the pump.
4. Turn regulator adjustment knob (G)
counterclockw ise until it stops, and gauge
(E) reads zero.
5. Open bleed type master valve (B).
6. Prime through d rain valve if necessary.
Note
Usually 1K high viscos ity m aterials.
NOTICE
Do not prime pump through drain/purge
valve using two component materials. Mixed
two-component materials will harden in valve
and result in clogging.
a. Place drain tube in a grounded waste pail.
Open drain/purge valve (J) slightly by rotating
counterclockwise.
Left: Xtreme Lower
Right: Dura-Flo
Lower
334645