GRAFIK Eye 3000
Series Control Units
supply power to, and control
the brightness of two, three,
four, or six zones of lighting.
GRAFIK Eye Control Units
control the intensity of all the
light sources in a room. You
can adjust the lights for a
special event or activity with
the press of a button!
○○○
LIGHTING CONTROL
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
LUTRON
LUTRON
PLEASE LEAVE FOR OCCUPANT
3000 Series
Installer’s Guide
Models 3100 and 3500
IMPORTANT! GRAFIK Eye lighting controls must be installed by a qualified electrician in accordance with all applicable
regulations. Improper wiring can result in personal injury or damage to GRAFIK Eye lighting controls or other equipment.
Always turn off circuit breaker/MCB or remove main fuse from power line before doing any work. To avoid overheating and
possible damage to equipment, do not install dimming devices to dim receptacles, motor-operated appliances, or
fluorescent lighting not equipped with Lutron Hi-lume
®
, Eco-10
, or Tu-Wire
Electronic Dimming Ballasts. In dimmed
magnetic low-voltage circuits, you can prevent transformer overheating and failure by avoiding excessively high current
flow: Do not operate GRAFIK Eye lighting controls with any lamps removed or burned out; Replace any burned out lamps
immediately; Use only transformers that incorporate thermal protection or fused primary windings. This lighting control is
designed for residential and commercial use. GRAFIK Eye Controls are designed for indoor use only.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Grafik Eye 3100 and is the answer not in the manual?

Grafik Eye 3100 Specifications

General IconGeneral
BrandGrafik Eye
Model3100
CategoryControl Unit
LanguageEnglish

Summary

STEP 1: Installing Control Units

Load Types

Identifies compatible load types for Control Units.

Installation instructions

Details preparation steps for mounting the Control Unit.

Line Voltage/Mains Wiring

Provides crucial notes for connecting line voltage and mains wires.

IMPORTANT WIRING NOTES!

Crucial safety and installation guidelines for wiring.

STEP 2: Installing Wallstations

Class 2/PELV Wiring

Explains Class 2/PELV wiring requirements for Wallstations.

Mounting

Illustrates the physical mounting procedure for the Control Unit.

Testing: Do the lights work?

Guides on how to test the installed Control Unit and lights.

IMPORTANT WIRING NOTES!

Emphasizes critical wiring guidelines for Wallstations.

Examples of Wallstations

Lists various types of compatible Wallstation models.

STEP 3: Setting Up GRAFIK Eye Control Units

How to enter and exit setup mode

Procedure for accessing and leaving the unit's setup mode.

Identifying the load type for each zone

Guide to setting the correct load type for each lighting zone.

What is a scene?

Defines scenes as preset light levels and fade times.

How to set up lighting scenes

Step-by-step guide to programming lighting scenes and fade times.

How to adjust light levels temporarily

Method for making temporary light level adjustments without saving.

How to set low-end trim—OPTIONAL

Procedure to adjust the lowest dimming level to prevent flicker.

Advanced Scene Programming Options—OPTIONAL

Advanced settings for programming scenes 5 through 16.

How to set an "unaffected zone” - OPTIONAL

Steps to configure a zone to remain unaffected during scene changes.

How to set Save Options—OPTIONAL

Guide to selecting different save options for scene settings.

STEP 4: Setting Up System Communications

Why do you set up communications?

Explains the purpose of system communication setup.

Do not set up communications . . .

Conditions under which communication setup is not required.

Do set up communications . . .

Conditions when system communication setup is necessary.

IMPORTANT!

Critical checks before setting up system communications.

Assign addresses to GRAFIK Eye Control Units

Process for assigning unique system addresses to Control Units.

Set up a Wallstation to “talk” to a “listening” Control Unit

Procedure for configuring Wallstations to communicate with Control Units.

Set up 2-way communication between 2 Control Units

Method for establishing two-way communication between Control Units.

Appendix A: More about Class 2/PELV Wiring

What is PELV?

Explains the definition and requirements of PELV circuits.

IMPORTANT WIRING NOTE!

Key considerations for proper wiring separation and cable types.

Small project: A Control Unit with up to three Wallstations

Wiring diagram and limits for small system configurations.

IMPORTANT WIRING NOTES!

Additional wiring guidelines for small projects.

Large project: Up to 8 Control Units and 16 Wallstations

Wiring overview for larger system configurations.

IMPORTANT WIRING NOTES!

Critical wiring notes for large projects.

Installing an external power supply

Guidance on installing external power supplies for expanded systems.

IMPORTANT WIRING NOTES!

Crucial guidelines for external power supply connections.

Appendix B: Special Mounting Considerations

Wallbox Mounting

Spacing guidelines for mounting multiple units in wallboxes.

Panel Mounting

Requirements for mounting units within enclosures.

Appendix C: Power Boosters and Interfaces

Wiring instructions

Steps for wiring Power Boosters and Interfaces.

Appendix D: GRX-TVI 0-10 Volt Ballast/Switching Interface

Specifications

Technical specifications for the GRX-TVI interface.

Installation

Instructions for mounting and wiring the GRX-TVI interface.

Appendix E: HP Dimming Modules (120V control feed only)

Appendix D: Wiring overview

General wiring overview for GRX Interfaces.

Specifications

Technical specifications for HP Dimming Modules.

Choose a mounting location

Guidelines for selecting an appropriate mounting location.

Mounting

Instructions for physically mounting HP Dimming Modules.

Appendix F: Infrared Transmitters

Infrared Transmitters

Information on handheld infrared remote controls.

Infrared Interference

Discusses potential IR interference issues and solutions.

Appendix G: Troubleshooting

Troubleshooting Guide

Covers common problems, their causes, and remedies for the system.