Troubleshooting
Noise:
If abnormal noise occurs, request service assistance.
Operating sounds due to air distribution from the interior/evaporator fan are normal.
If sheet metal parts, front panels or panels in front of the “compressor” compartment are
noisy due to vibrations, these might be open. Close the panels.
Frosting inside compartment:
Ambient humidity too high.
The door is opened too often.
The door is left open for too long.
Damaged door gasket. Check it thoroughly for damages.
Poor cooling performance:
Ambient temperature too high.
The door is opened too often and/or open for too long.
The door is left open.
Damaged door gasket.
Temperature set point adjusted too high.
Product is too packed with food - air inlet/outlet blocked.
Shelving not placed as intended, resulting in poor air circulation.
Always mount a shelve in the lowest possible position. No food below the lowest shelve or
above the upper load limitation.
Warm or hot foods inside the product (not intended use).
Defrost in progress. The cabinet temperature may rise temporarily during the defrost cycle,
but it will not affect the food inside. The defrost symbol of the controller is displayed.