Noise:
• If abnormal noise occurs, request service assistance.
• Operating sounds due to air distribution from the interior/evaporator fan are normal.
• If sheet metal parts, front panels or panels in front of the “compressor” compartment are
noisy due to vibrations, these might be open. Close the panels.
Frosting inside compartment:
• Ambient humidity too high.
• The door is opened too often.
• The door is left open for too long.
• Damaged door gasket. Check it thoroughly for damages.
Poor cooling performance:
• Ambient temperature too high.
• The door is opened too often and/or open for too long.
• The door is left open.
• Damaged door gasket.
• Temperature set point adjusted too high.
• Product is too packed with food - air inlet/outlet blocked.
• Shelving not placed as intended, resulting in poor air circulation.
• Always mount a shelve in the lowest possible position. No food below the lowest shelve or
above the upper load limitation.
• Warm or hot foods inside the product (not intended use).
• Defrost in progress. The cabinet temperature may rise temporarily during the defrost cycle,
but it will not affect the food inside. The defrost symbol of the controller is displayed.