HT812/HT814 Administration Guide
a duration range from 100 to 10000 ms. Default value is 200.
Enables the FLASH button to be used for terminating calls. Default is Yes.
Defines the time period when the cradle is pressed (Hook Flash) to simulate FLASH. To
prevent unwanted activation of the Flash/Hold and automatic phone ring-back, adjust
this time value. HT812/HT814 support a range from 40 to 2000 ms. Default values are
300 minimum and 1100 maximum.
Specifies the on-hook time for an on-hook event to be validated. HT812/HT814 support
a range from 40 to 2000 ms. Default value is 400.
Adjusts the voice path volume.
• Rx is a gain level for signals transmitted by FXS
• Tx is a gain level for signals received by FXS.
Default = 0dB for both parameters. Loudest volume: +6dB Lowest volume: -6dB. User
can adjust volume of call using the Rx gain level parameter and the Tx gain level
parameter located on the FXS port configuration page. If call volume is too low when
using the FXS port (ie. the ATA is at user site), adjust volume using the Rx gain level
parameter under the FXS port configuration page. If voice volume is too low at the
other end, user may increase the far end volume using the Tx gain level parameter
under the FXS port configuration PAGE.
Disable Line Echo
Canceller
Disables the LEC will per call base. Recommended for FAX/Data calls. Default is No.
Disable Network
Echo Suppressor
Disables the NEC will per call base. Recommended for FAX/Data calls. Default is No.
Outgoing Call
Duration Limit
Defines the call duration limit for the outgoing calls, Default is 0 (No limit).
Configures ringing frequency for your phone. 15-60 Hz, Default is 20 Hz.
Configures the ring tone cadence preferences. User has 10 choices. The configuration,
completed in Distinctive Ring Tones block in the same page, applies to ring tones
cadences configured here.