5 Trouble shooting and alerts 5.1 User related notices
Error
code
Meaning
Cause
Remedy
118 Drain valve
not closed
The drain valve has
opened during an ac-
tive process in the
machine.
Close the drain
valve and reset the
alarm by pressing
the STOP button.
132 Clean level
sensor
Level sensor is probably
dirty or water is not ex-
changed after longer
shut down period.
Lower the level and
clean the level sen-
sor in the wash tank.
Refill the tank. If sen-
sor is already
cleaned, reset the
error and set the
machine in heating
mode for continued
heating