134
Menu references
Service menu
3200K Calibr
3200K Calibr Off, On S - Select to run 3200K Calibration
3200K Reset Fact, Cust S - Resets 3200K Calibration data
Vref Calibr-
Vref Calibr Off, Running S - Select to run Vref Calibration
Status Unknown, Ok, Ready,
Busy, Error, Abort, Filter
Cap
S - Shows status of Vref Calibration
Progress 0%..100% S - Progress of Vref Calibration procedure
Black Calibr
Black Calibr Off, Running 3 Select to run Black Calibration
Note: this takes up to 80 seconds to complete
Status Unknown, OK, Error,
Fatal Error, Needed,
Temp Low, Temp Unst,
TimeOut, Temp Range,
FullBlRec, Filter Cap,
Running, Ready, Failed,
Aborted
3 Shows status of the Black Calibration procedure
Progress 0%..100% 3 Progress of Black Calibration procedure
Act Temp -128 C..127 C 3 Shows actual (current) camera temperature.
White Calibr
User Calibr Off, Running S Select to run User White Calibration
Status Unknown, Error, Busy,
OK, Ready, VidLvl
S Shows status of White Calibration procedure
Progress 0%..100% 3 Progress of White Calibration procedure
User Clear Exec, ... S Clears User White Calibration data
White Corr Off, On S Enable or disable White Correction
Function: Values: U: F: Description:

Table of Contents