18
.During the wiring, the wiring terminal or the single-core wire must be used; the
direct wiring between the multi-core wire and wiring board would cause fire.
.All wiring should be done strictly in accordance with the wiring diagram;
otherwise the improper wiring would cause the air conditioning unit running abnormally
or damaged.
.Do not let the electric wires touch the refrigerant pipe, the compressor, the fan
or other moving parts.
.Do not modify the wiring inside the indoor unit randomly; otherwise the
manufacturer won’t assume any responsibility for the damage or abnormal running of
the unit.
16 Wiring of the Power Cord (single-phase)
CAUTION!
The power supply for each indoor unit must be uniform.
. Dismantle the cover of the electric box of the indoor unit.
. Let the power cord go through the rubber ring.
. Connect the wiring (communication) through the piping hole of the chassis and
the bottom of the appliance upward, then connect the brown wire to the Terminal board
“3”;black wire(the communication wire) to the Terminal board“2”;blue wire to the
Terminal board“N(1)”,and connect the earthing wire to the screw terminal on the electric
box. Clamp them with the corresponding wire clamp packed in the chassis.
. Fix the power cord tightly with the binding wire.
Fig.21
XT1
N(1)
2
3
N(1)
2 3
PE
OUTDOOR UNIT
BU
BK
BN