Introduces basic models, energy efficiency, comfort features, and advanced technology features.
Covers humanized operation, intelligent management, piping, operating range, module switching, and static pressure design.
Provides detailed specifications for various outdoor unit models, including capacity, power, and dimensions.
Describes the function and types of C&H Mode Exchangers used for connecting indoor and outdoor units.
Illustrates possible combinations of single outdoor units for different capacities.
Presents piping diagrams for various outdoor unit models.
Lists and explains the main functions of components used in the internal piping system.
Provides tables for correcting cooling capacity based on ambient and indoor conditions.
Details factors to adjust heating capacity when units face frosting or defrosting conditions.
Presents sound pressure levels across different octave bands for various HP outdoor units.
Provides diagrams showing external dimensions and gravity center points for specific outdoor unit models.
Guidelines for selecting installation sites and details external dimensions for outdoor units.
Specifies clearances for dual and triple module units, and considerations for walls.
Provides guidance on installing outdoor units considering seasonal wind and snow conditions.
Outlines dimensions, site selection, and installation instructions for C&H Mode Exchangers.
Illustrates piping connections and specifies allowable pipe lengths and drop heights.
Details pipe size requirements for connecting outdoor units to the first indoor branch and for multi-module systems.
Guides on branch selection, piping sizes, and connection methods for mode exchangers and indoor units.
Explains connection methods when indoor unit capacity exceeds 48500Btu/h.
Describes the screw fastening mode for connecting communication lines.
Guides on material type, wire size, and remarks for communication cables.
Details connection methods and procedures for communication cables between units, including multi-module systems.
Explains different modes for connecting indoor units to wired controllers.
Describes how to connect air duct-type indoor units to remote receiving LED panels.
Lists the quantity and labels for external power, communication, and control interfaces.
Provides diagrams illustrating external connection methods for single and modular units.
Details calculating refrigerant for piping based on liquid pipe length and diameter.
Explains calculating refrigerant for each module based on capacity and IDU quantity.