Unit Control
15
Status of the thermostat
Thermostat
Off/Cool/Heat
16
Status of other thermal source
Other thermal
On/Off
17
Status of the 2-way valve
2-way valve
On/Off
18
Status of antifreeze
HP-Antifree
On/Off
19
Status of the door guard
Gate-Ctrl.
Card in/Card out
20
Status of the 4-way valve
4-way valve
On/Off
21
Status of disinfection
Disinfection
Off/Running/Done/Fail
22
Status of the flow switch
Flow switch
On/Off
3.2.5.2 Parameter Viewing
[Operation Instructions]
1. At the
VIEW
page, by touching
Parameter
‖, it is able to view each parameter of the unit, as
shown in the figure below.
Parameter View Page
Viewable Parameters
No.
Full Name
Displayed Name
1
Environmental temperature
T-outdoor
2
Suction temperature
T-suction
3
Discharge temperature
T-discharge
4
Defrosting temperature
T-defrost
5
Entering water temperature of the plate type heat exchanger
T-water in PE
6
Leaving water temperature of the plate type heat exchanger
T-water out PE
7
Leaving water temperature of the auxiliary heater
T-optional water Sen.
8
Water tank temperature
T-tank ctrl.
9
Floor debug target temperature
T-floor debug
10
Floor debug runtime
Debug time
11
Liquid line temperature
T-liquid pipe
12
Vapor line temperature
T-gas pipe
13
Economizer inlet temperature
T-economizer in
14
Economizer outlet temperature
T-economizer out
15
Remote room temperature
T-remote room
16
Discharge pressure
Dis. pressure
17
Weather-dependent target temperature
T-weather depend
3.2.5.3 Error Viewing
[Operation Instructions]
At the
VIEW
page, by touching
Error
‖, it is able to view errors of the unit, as shown in the figure