17
Technical Information
Service Manual
OUTDOOR UNIT
N1(N)
SWING-UD
AP1
BU
2
XT
N(1)
SWING-LR
TERMINAL
BLOCK
BK
AC-L
BN
BU
BK
YEGN
PRINTED CIRCUIT BOARD
PE
BN
BU
YEGN
POWER
L
N
T-SENSOR
TEMP.
ROOM
RT1
RT2
θ
θ
COM-DISPLAY
COM-MAIN
AP3
M1
YEGN
C
FAN
FAN
PE
MOTOR
SENSOR
TEMP.
TUBE
SENSOR
L
N
UP-DOWN
STEP
MOTOR
LEFT-RIGHT
STEP
MOTOR
BU
COMP
CAP.
WIFI CONTACT
CN42
AP2DISPLAY
M2
M3
OPTIONAL
X2
CONNECTOR
3
BN
BN
4WOF
X1
OG
VT
L2
OUTDOOR UNIT
N
AP1
BU
2
3
XT
N(1)
TERMINAL
BLOCK
BK
AC-L
BN
BU
BK
BN
YEGN
PRINTED CIRCUIT BOARD
PE
T-SENSOR
TEMP.
ROOM
RT1
RT2
θ
θ
M3
M2
COM-DISPLAY
COM-MAIN
DISPLAY
AP2
AP3
CN42
M1
YEGN
C
FAN
PE
MOTOR
SENSOR
TEMP.
TUBE
SENSOR
UP-DOWN
STEPPING
MOTOR
LEFT-RIGHT
STEPPING
MOTOR
COM
CAP.
(OPTIONAL)
WIFI
CONTACT
(COM-OUT)
CN3
CN2
CN449
(UD-SWING)(LR-SWING)(FAN2)
NOTE:Motor
ground only
applies to
the iron
shell motor.
600007065912