86
Installation and Maintenance
Service Manual
11.2 Removal Procedure of Outdoor Unit
Caution: discharge the refrigerant
completely before removal.
11. Removal Procedure
Step Procedure
1. Before disassembly
2. Remove handle and valve cover
Remove the screws xing handle
,
valve cover and then
remove them.
3. Remove top cover
Remove the screws xing top panel and then remove
the top panel.
Handle
Valve cover
Top cover
NOTE: Take heat pump model for example.