24
Technical Information
Service Manual
6. Function and Control
set only in heating mode). When timer or auxiliary heating icon
is blinking, it means this function can be set. Press "" or ""
button to set function. If theres no operation change within 5s
after setting is nished, the function setting will be conrmed. Or
press Function button again to exit or conrm the function. When
the function is selected through Function button, if the unit is not
turned off and no remote control signal is received within 2min,
pressing FUNCTION button again to circulate from the previous
set function. After 2min or the unit is turned off or remote control
signal is received, pressing FUNCTION button again to circulate
from timer icon. (Note: Only when the unit is under heating mode
and with auxiliary heating function, auxiliary heating function
can be turned on or off through FUNCTION button.)
Under off status, if the unit is in X-FAN status, press Function
button to turn off the unit directly; if the unit is not in X-FAN
status, press FUNCTION button to set timer ON.
5. ▲ / ▼ button
After each pressing of "" or "▼" button, set temperature will
increase or decrease 1°C. Temperature adjustment range is
16°C~30°C. This button is invalid under auto mode. Timer setting
can be set in 1h increment among 0~24h. When it is adjusted to
auxiliary heating function setting through Function button, press
this button to turn on or turn off auxiliary heating. (Note: auxiliary
heating is valid only for the model with this function.)
Hold "" and "▼" buttons for 3s and the air conditioner will
display "LC", which indicates buttons are locked. Any button
under on status or ON/OFF button and function buttons under
off status are all invalid. Hold these two button for 3s again to
release the lock.
6. / button
Left and right swing: this button controls the left and right
swing motor, single press it to switchover between ON and OFF.
Up and down swing: this button controls the up and down
swing motor, single press it to switchover between ON and OFF.
Icon function introduction
Operation display
It indicates the air conditioner is put through the power. Under on
status, this indicator is on; under off status, this indicator is off.
Timer display
When this indicator is on, it indicates the timer function is turned
on.
Heating display
When this indicator is on, it indicates the heating mode is turned
on.
Defrosting display
When this indicator is on, it indicates the defrosting function is
turned on.
Dry display
When this indicator is on, it indicates the dry mode is turned on.
E-Heater display
When this indicator is on, it indicates the E-heater function is
turned on. (Only available for some heat pump unit)
Cooling display
When this indicator is on, it indicates the cooling mode is turned
on.
Fan display
When this indicator is on, it indicates the fan mode is turned on.
Fan speed display
Displays the fan speed. The fan speed is displayed as below:
(low)
(medium) (high)
(turbo)