INSTALLATION 
112 
7.8  Instructions for DIP Switch 
  2 digits DIP is adopted to assign the address when using multi-BU modules and the address cannot be 
repeated in the same unit. 
  One outdoor unit can connect to no more than 3 BU modules. 
  “ON” side means "ON" and the opposite side represents "OFF". (Note: The black part is lever.)   
 
DIP Code 
Number 
DIP 1  DIP 2 
Icon Address 
1 OFF OFF 
 
BU 1 
2 OFF ON 
 
BU 2 
3 ON OFF 
 
BU 3 
 
 
7.9  Electrical Wiring Work for Indoor Unit 
1)  Open surface panel.   
2)  Remove the electrical box cover.   
3)  Route the power connection cord from the back of the indoor unit and pull it toward the front through 
the wiring hole upward.   
4)  Connect the wiring (communication) through the piping hole of the chassis and the bottom of the 
appliance upward, then connect the brown wire to the Terminal board “3”;black wire(the 
communication wire) to the Terminal board“2”;blue wire to the Terminal board “N(1)”,and connect the 
ground wire to the screw terminal on the electric box. Clamp them with the corresponding wire clamp 
packed in the chassis.   
5)  Reassemble the electrical box cover.   
6)  Recover the surface panel.   
7)  The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the 
copper tube.