6  PIPING DIAGRAM 
Schematic Diagram of Super Free Match Series Inverter Heat Pump Multi System 
 
The units start to work once the power is switched on.   
During the cooling operation, the low temperature, low pressure refrigerant gas from the heat exchanger of 
each indoor unit gets together and then is taken into the compressor to be compressed into high temperature, high 
pressure gas, which will soon go to the heat exchanger of the outdoor unit to exchange heat with the outdoor air 
and then is turned into refrigerant liquid. After passing through the BU module, the temperature and pressure of 
the refrigerant liquid will further decrease and then go the main valve. After that, it will be divided and go to the 
heat exchanger of each indoor unit to exchange heat with the air which needs to be conditioned. Consequently, the 
refrigerant liquid become low temperature, low pressure refrigerant gas again. Such a refrigeration cycle goes 
round and round to achieve the desired refrigeration purpose.   
During the heating operation, the four-way valve is involved to make the refrigeration cycle run reversely. 
The refrigerant radiates heat in the heat exchanger of the indoor unit (so do the electric heating devices) and 
absorb heat in the heat exchanger of the outdoor unit for a heat pump heating cycle so as to achieve the desired 
heating purpose.