Super Free Match 
 Service Manual 
 
    PRODUCT 
5 
2  NOMENCLATURE 
2.1  Nomenclature of Outdoor Unit 
GW  □  □  (□)  □  □  □  □  O 
1 2 3 4 5 6 7 8 9 
 
NO. Description  Options 
1 GW Free-Match Code 
2  Cooling Function  C: Cooling Only        H: Heat pump 
3  Compressor Frequency  D:DC inverter rotor type 
4  Cooling Capacity 
48 represents 48000Btu/h 1kW=3.412KBtu 
S represents super free match 
5  Climate Type  T1 
6  Power Supply 
M:380-415V-3Ph-50Hz;    D: 208/230V-1Ph-60Hz 
K:220-240V-1Ph-50Hz 
7  Refrigerant  3-R410A 
8  Design No.  C :Third generation 
9 O O:Outdoor unit 
2.2  Nomenclature of BU Module 
 
2.3  Nomenclature of Indoor Unit 
G  □  □  (□) □  -  □  □  □  □  □  □  /  I 
1 2 3 4 5    6 7 8 9 10 11   12 
 
NO. Description  Options 
1 G GREE  
2 Product Type 
W: Wall mounted type      F:Duct type 
K:Cassette type   E:Console   T:Floor ceiling type 
3  Cooling Function  C: Cooling Only        H: Heat pump 
4  Cooling Capacity  12 represents 12000Btu/h     1kW=3.412KBtu 
5  Series  Alphabets: Series code + Shell code 
6  Power Supply  K:220-240V-1Ph-50Hz;   D: 208/230V-1Ph-60Hz 
7 Refrigerant 3-R410A 
8  Compressor Frequency  D:DC inverter rotor type 
9 Climate Type T1 
10  Panel Code  1 Alphabet +1 Numeral 
11  Design No.  A :First generation 
12 I I:indoor Unit 
FX  □  □  □ 
1 2 3 4 
No.   Description  Options 
1  Assembly type  FX-branch module 
2 Body code A、B、C…… 
3  Number of port  2-two ports; 3-three ports; 5-five ports 
4 Connection method A-Flare;   B-Braze