151 
6.1.3 Disassembly and Assembly of 4-way valve   
Remarks: Prior to the assembly of the compressor, make sure there is no refrigerant in the pipeline and the power 
supply is cut off.   
Steps Illustrations Operation Instructions 
1.Remove the magnet 
coil of the 4-way valve 
 
a) Unscrew the fixed 
screws of the magnet 
coil; 
b) Remove the magnet 
coil. 
2.Disconnect the 4-way 
valve and the 
connecting pipe 
 
Solder off the connecting 
pipes.  
Note: never let the flame 
contact any other 
component. 
3.Replace the new 
4-way valve 
 
Install the new 4-way 
valve 
4.Solder the new 4-way 
valve and install the 
magnet coil. 
 
Solder the connecting 
pipes 
Note: To avoid heat 
damage the internal 
structure of the 4-way, 
wrap it to be brazed with 
sufficient wet cloths.