67
Installation and Maintenance
Service Manual
25 PFC protection HC
Flash 
6 times 
every 3s
During cooling and drying 
operation, compressor and 
outdoor fan stop while indoor 
fan operates. During heating 
operation, all loads stop.
See 9.3 (diagnosis of 
PFC protection)
Refer to maintenance 
owchart
26
Desynchronizing 
of compressor
H7
Flash 
7 times 
every 3s
During cooling and drying 
operation, compressor and 
outdoor fan stop while indoor 
fan operates. During heating 
operation, all loads stop.
See 9.3 (diagnosis 
of IPM protection, 
desynchronizing 
malfunction, 
overcurrent protection 
of phase current of 
compressor)
Refer to maintenance 
owchart
27 H0
Flash 
10 times 
every 3s
See 9.3(diagnosis of 
overheating prevention 
and overload 
protection)
Refer to maintenance 
owchart
28 Failure startup Lc
Flash 
11 times 
every 3s
During cooling and drying 
operation, compressor and 
outdoor fan stop while indoor 
fan operates. During heating 
operation, all loads stop.
See 9.3 (diagnosis of 
failure startup)
Refer to maintenance 
owchart
29
Circuit 
malfunction of 
phase current 
circuit detection 
for compressor
U1
Flash 
13 times 
every 3s
During cooling and drying 
operation, compressor and 
outdoor fan stop while indoor 
fan operates. During heating 
operation, all loads stop.
Hardware malfunction 
of outdoor units main 
board;
1. Replace outdoor 
units main board AP1