4
Technical Information
Service Manual
2.2 Operation Characteristic Curve
Cooling Heating
Cooling
Heating
24K
0
2
4
6
8
10
12
14
020406080100 120
0
2
4
6
8
10
12
14
020406080 100
120
Conditio
n
Indoor:DB27°C
WB19
°C
Indoor air flow: Super High
Pipe length:5m
Condition
Indoor:DB 20°C
Indoor air flow: Super High
Pipe length:5m
Compressor Frequency(Hz)
Compressor Frequency(Hz)
Current(A)
Current(A)
2.3 Capacity Variation Ratio According to Temperature
Cooling
Heating
Capacity ratio(%)
Outdoor temp(°C)
-30
200
180
160
140
120
100
80
60
40
20
0
-25 -20 -15 -10 -5 05 710
Capacity ratio(%)
Outdoor temp. (°C)
51494745434139373533312927252321
110
100
90
80
70
60
50
53
Condition
Indoor:DB 27°C WB19°C
Indoor air flow: Super High
Pipe length:5m