58
Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Step Procedure
2.Remove horizontal louver
Open the panel.
Panel
Axile bush
Location of step motor
Horizontal louver
Loosen the clasp shown and
outwards to remove them.
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
a.
b.
horizontal
louver